Spike result: Windows SNMP status (task 1.3)

Status: answered (paper out and per-queue identification confirmed in a recheck the same evening) · Date: 2026-09-15 · Run by: Ahmed Alrifai · Kit: spikes/windows-snmp/

Question

  1. Which SNMP requests (version, community, PDU type, OIDs, timing) does the Windows Standard TCP/IP port monitor send for a queue on 127.0.0.1 with SNMP status enabled?
  2. Which responses make the queue show ready, low paper (warning only), paper out, door open and offline?
  3. With two queues pointing at 127.0.0.1, can the responder tell them apart (device index, community)?

Environment

Item Value
Windows edition, version, build Windows 11 Pro 10.0.26200, physical PC (MS-7C02), Secure Boot on
SNMP Service installed / running before the test Not installed (Start-Service SNMP: "Cannot find any service with service name 'SNMP'"); UDP 161 was free
Python / uv version CPython 3.13 via uv 0.7.13
Wireshark and Npcap versions (if used) Not used; snmp-log.jsonl was the only capture
Get-PrinterPort emupos-spike (SNMPEnabled, SNMPCommunity, SNMPIndex) True, public, 1 (port 127.0.0.1:9200, protocol RAW, monitor TCPMON.DLL)

Deviations from the kit:

  • TCP 9200 instead of 9100. Port 9100 was held by lghub_updater.exe (Logitech G HUB), and its service could not be stopped ("Cannot open LGHUBUpdaterService service"). The fake printer ran with --tcp-port 9200, the queue with -PortNumber 9200, and the second queue on 9201.
  • Print Spooler was stopped (StartType Manual). Until it was started, Add-PrinterDriver failed with 0x800706d9 and Get-PrinterPort with 0x800706ba ("The spooler service is not reachable"). It was started for the test; the cleanup then set it to Disabled by mistake, and the recheck put it back to Manual and stopped it.
  • "Generic / Text Only" was not installed; create_queue.ps1 installed it with Add-PrinterDriver once the Spooler ran.
  • Log times below are UTC; the PC's clock was UTC+2. notes.txt has two lines "stopped the Windows SNMP Service" that were pasted without editing; the service does not exist on this PC.

Observations

  1. During create_queue.ps1: SNMP requests immediately (logged 15:01:58 and 15:18:45 for the two creations): GETNEXT 1.3.6.1.4.1.2699.1.2, then GET sysDescr.0, then GET of the three status objects for index 1. No TCP connection to the print port until a job was sent.
  2. Polling, all from one UDP source port per Spooler run (58312, later 55955):
  3. Discovery pair (GETNEXT 1.3.6.1.4.1.2699.1.2 + GET sysDescr.0) every 10 minutes (15:18:45, 15:28:45 … 16:28:45), often sent twice 1 s apart. 2699.1.2 is under the Printer Working Group enterprise number; the kit answered noSuchName and Windows carried on.
  4. Status GET every 10 minutes while the printer is healthy (15:49:39, 15:59:40, 16:09:40, 16:21:37, 16:27:07 → 16:37:07), and sometimes right around a job (16:11:37, 15:39:49).
  5. No reply (run A): the same GET 3 times 10 s apart, repeated every 60 s.
  6. noSuchName reply (run B): every 60 s.
  7. Error state reported (runs F and G): again after 60 s, then every 30 s.
  8. Requests for the default queue: version v1 only (no v2c seen); community public (the port's -SNMPCommunity); PDU types GETNEXT and GET; status OIDs in one GET, in this order: 1.3.6.1.2.1.25.3.2.1.5.1 (hrDeviceStatus), 1.3.6.1.2.1.25.3.5.1.1.1 (hrPrinterStatus), 1.3.6.1.2.1.25.3.5.1.2.1 (hrPrinterDetectedErrorState). sysObjectID, sysUpTime, hrDeviceType and hrDeviceDescr were never requested.
  9. Status matrix (each run waited 2 minutes, printed one Out-Printer job, waited 15 s, then read Get-Printer and Settings):
Run Fake printer Settings status text Get-Printer PrinterStatus Test job printed / held Requests seen
H not running Offline Normal (job "Printing, Retained") retried; delivered at 15:32:38 when run A started listening none (nothing listening)
A silent Offline Offline held status GET ×3 every 60 s, unanswered
B nosuch Offline Offline held (A and B jobs) status GET every 60 s, noSuchName
C ready Offline in the first C run (15:39:58), Idle in a repeat (16:06:52) Normal printed; held A and B jobs printed 0.1 s after the first ready reply (15:39:49) status GET answered ⅔/00
D low-paper Idle Normal printed (16:11:37) status GET at 16:09:40 and 16:11:37 answered 3/3/80
E paper-out Idle Normal printed (16:14:28) none: no poll between 16:12:28 and 16:15:37, so paper out was never reported (see the recheck)
E2 paper-out, 2 octets Idle Normal printed (16:17:37) discovery pair only (16:18:45); no status GET (see the recheck)
F door-open Door open DoorOpen held status GET at 16:21:37 answered 5/1/08, then every 30 to 60 s
G offline Offline Offline held status GET at 16:24:07 answered 5/1/02, then every 30 s

Back to ready (step 2.5): the status GET at 16:27:07 answered ⅔/00, and the held F and G jobs printed at once.

  1. Time from changing state to Windows showing it: from a healthy state, until the next 10-minute status poll (up to 10 minutes; runs E and E2 fell entirely between polls). From an error state, within 30 to 60 s. Settings did not always refresh: the first run C showed Offline in Settings while Get-Printer already said Normal.
  2. Two queues: queue 2 (-DeviceIndex 2 -Community back, port 9201) sent community back and index 2 in its first status GET at 16:30:43 (…25.3.2.1.5.2, …25.3.5.1.1.2, …25.3.5.1.2.2, v1). The fake printer was still answering index 1 only, so it replied noSuchName. Queue 2 then sent no further request before the log ends at 16:37:07, unlike queue 1 in run B, which re-polled every 60 s. --index-state 2=paper-out gave Idle / Idle (both Normal) and --community-state back=paper-out gave Idle / Idle, but neither run received a request, and paper out was not observable anyway (row E). Not observed in this run; confirmed by index in the recheck.
  3. Port 161: no conflict. The Windows SNMP Service is not installed on this PC.
  4. Wireshark: not used.
  5. Bytes of the Out-Printer test job: 0d 0a 0a 0a 0a 0a 0a + 10 spaces + emupos spike run H + 0c (36 bytes). No ESC/POS commands; the "Generic / Text Only" driver renders text with CR LF line ends, a top margin of line feeds, a left margin of spaces and a form feed at the end. Notepad jobs (step 2.5) had the same shape with a 7-space margin. The Arabic line المجموع 4.75 arrived as ....... 4.75 (one . per Arabic character), and the empty line in receipt.txt was not printed.
  6. Admin rights: -SkipAdminCheck not tried.
  7. Cleanup: remove_queue.ps1 removed both queues, but Remove-PrinterPort failed for both ports with 0x800700aa ("The specified port is in use by one or more printers"), although neither queue had jobs left (JobCount 0 at 18:32 and 18:35 local). Restart-Service Spooler followed by Remove-PrinterPort removed both.

Recheck (same PC, 19:42 to 19:56 local, 17:42 to 17:56 UTC)

Runbook: each row set the fake printer's state first, then deleted and recreated the queue so that Windows would ask for status straight away, then printed one test job after 45 s. Results in re-status.txt and snmp-log-recheck.jsonl. The Spooler had been left Disabled by the first run's cleanup (it was Manual before); it was set back to Manual for the recheck.

Row Fake printer Settings Get-Printer Test job Status reply Windows got
1 (control) door-open Door open DoorOpen held 5/1/08 at creation
2 paper-out Out of paper PaperOut held 5/1/40 at creation
3 paper-out, 2 octets Out of paper PaperOut held 5/1/40 00 at creation
4 (control) ready Idle Normal printed ⅔/00 at creation
A index 1 ready, index 2 door-open emupos-spike Idle, emupos-spike2 Door open Normal / DoorOpen printed (to emupos-spike) index 1: ⅔/00; index 2: 5/1/08
B index 1 door-open, index 2 ready emupos-spike Door open, emupos-spike2 Idle DoorOpen / Normal printed (see below) index 1: 5/1/08; index 2: ⅔/00
  • Paper out shows as "Out of paper" and holds jobs, with the error state as one octet or two.
  • Two queues on 127.0.0.1 with the same community and different -SNMP indexes each show their own printer's state, in both directions.
  • A fault change is picked up while Windows is already polling fast: before row 2's queue was recreated, the old queue's 30 s poll at 17:44:00 already read paper out, and at 17:47:14 read ready.
  • Windows does not always ask for status as soon as a queue is created. emupos-spike2 got only the discovery pair at creation and its first status GET 45 s later, right after a job went to emupos-spike. In row B the test job went to emupos-spike at 17:55:06.336, before Windows had asked index 1 for status, so it printed although the printer was in door open; the status GET followed 11 ms later and the queue then showed DoorOpen.

Decision

Objects the responder must answer (task 10.3), SNMP v1 (keep v2c as the spec says; Windows did not use it):

  • GETNEXT 1.3.6.1.4.1.2699.1.2: a noSuchName (v1) or endOfMibView (v2c) reply is enough.
  • GET sysDescr.0 (1.3.6.1.2.1.1.1.0).
  • GET hrDeviceStatus.N, hrPrinterStatus.N, hrPrinterDetectedErrorState.N in one request, where N is the port's SNMP index.
emupos fault hrDeviceStatus hrPrinterStatus hrPrinterDetectedErrorState Windows shows
none running(2) idle(3) 00 Idle (observed, run C)
paper-near-end warning(3) idle(3) 80 (lowPaper) Idle; no warning, jobs print (observed, run D)
paper-out down(5) other(1) 40 (noPaper) Out of paper; Get-Printer PaperOut; jobs held (observed in the recheck, rows 2 and 3)
cover-open down(5) other(1) 08 (doorOpen) Door open; Get-Printer DoorOpen; jobs held (observed, run F)
offline down(5) other(1) 02 (offline) Offline; jobs held (observed, run G)

No reply and noSuchName both show Offline and hold jobs (runs A and B).

  • Per-queue identification: [x] device index (-SNMP) [ ] community [ ] not possible (spec change needed). Reason: each port's status GET carries its own index, and the recheck showed two queues with the same community and indexes 1 and 2 each displaying their own printer's state (rows A and B). Community was not tested end to end.
  • hrPrinterDetectedErrorState length: [x] 1 octet [ ] 2 octets. Reason: Windows decoded the 1-octet values 08, 02 and 40; the 2-octet 40 00 gave the same result, so one octet is enough.

Impact on specs and tasks

  • windows-print-queue spec, "Queue status reflects printer state": nothing contradicted. Paper out, door open and offline show distinctly, and paper-near-end as a low-paper warning matches (Windows shows nothing and keeps printing). "Each queue reports its own printer" works with a distinct SNMP index per port. The documentation must say that Windows polls a healthy printer about every 10 minutes, so a new fault can take up to 10 minutes to appear in Windows, while clearing a fault shows within a minute. "SNMP status responder": Windows used v1 GET and GETNEXT with the objects above. "One-way printing limitation": also document that ordinary applications (Notepad, Out-Printer) print through "Generic / Text Only" as plain text, and characters outside its code page such as Arabic become ..
  • design.md D7 and the Open Question on SNMP objects: the object list and value mapping above answer the question. D7's "passes the application's bytes through unchanged" holds only for RAW jobs; GDI printing is rendered to plain text. RAW submission was not exercised here.
  • tasks 10.1 (SNMP settings per port): give each printer's port a distinct -SNMP index; the responder has to answer that index from the moment the port exists, because queue 2 stopped polling after one noSuchName. Detect a stopped Spooler (0x800706ba) with a clear fix, and install "Generic / Text Only" when missing. 10.2: Remove-PrinterPort can fail with 0x800700aa right after the queue is removed; restart the Spooler (or retry) before deleting the port. 10.3: the objects above. 10.4: the SNMP Service may be absent entirely. 10.5: submit a RAW job and check it arrives unchanged, and check emupos faults against the table above. A job sent before Windows's first status poll of a new queue prints even when the printer has a fault, so verification should wait for the queue to show the fault first. 12.6 doctor: name the process holding a configured TCP port (here lghub_updater.exe on 9100) and report a stopped Spooler when a queue exists.